Friday, April 29, 2016

Daily Post 12

Recently I've been rather busy, so I apologize for the lack of updates regarding our project. Recently we've made some serious progress.

We've received almost every part ordered, we need only to retrieve the reverse osmosis filter and a caulk gun from one of our members' house address, which should not take long. We've advanced some of the components we've received, shaping them and adjusting them to the specification that we desire. For example, we have reshaped two of the 3 gallon reservoirs in order to fit into the system appropriately. After the modifications, the reservoirs now can be attached to the clear piping that we are soon to order. (The piping is clear so that the UV light penetrates the water flowing through it.)

Now we must get together for a solid two or more hours to finish adjusting components as necessary. Afterwards, most of the work will be assembling our apparatus and putting a few finishing touches...

Hopefully, everything goes to plan. However, we have taken steps to ensure that even if something were to go wrong, we have a way to repair the situation. I'm confident in our progress.

Wednesday, April 27, 2016

Trip to the hardware store

Yesterday, instead of attending lab, our group took a trip to a local hardware store to get some parts. By now we have received almost all of the parts we ordered so we can start to make some progress. At the hardware store we bought some PVC components and silicone to get started connecting things.

Tuesday, April 19, 2016

Daily Post 11: New Developments!

Today in lab we have been extremely productive, solving both the issues with the UV light bulb and fixture as well as further developing details in how the design of the water purification unit will operate. Tomorrow there will be a post detailing parts of the new design we have decided to implement.

I contacted the UV light bulb's company and spoke with a representative about the potential issues between the current fixture and their UV bulb. The conclusion seemed to be that it may have been a malfunctioning bulb, since the amount of voltage, wattage, and amperage was confirmed compatible between the two components. I decided, since even then we weren't entirely sure, to purchase a fixture that the company guarantees will work with the bulb, as well as a replacement bulb. It should arrive in 4-5 business days.

Furthermore, we have been advised to consider a method of determining how successful our project is, and are currently doing research on the possibilities we may use. So far, it seems that we can purchase a water testing kit that can test bacteria, pH, pesticides, chlorine, hardness, lead, and nitrates. We believe this may be sufficient, but will conduct additional research to verify that the water testing kit is our best option.

Monday, April 18, 2016

Daily Post 10

Unfortunately I haven't found the opportunity to contact the light bulb company to ask for information of what went wrong, due to needing to finish a large workload. Now that evening is approaching, their lines are closed for now. However, I have set a goal (and an alarm) to ensure that I make the call tomorrow. Additionally, since the group is meeting in lab tomorrow, we may discuss it further and come to alternative consensus. I am optimistic.

Sunday, April 17, 2016

Daily Post 9: UV Bulb Diagnostics

After the bulb has gone up in smoke, I have done some research. My research seems to hint that the UV bulb itself malfunctioned when shipped, and instantly burnt out due to component failure. However, another possibility revealed is that the voltage may have been too high for it to handle.

This is conflicting, because it seems like either possibility is likely, but the only method of truly finding out is to buy another of the same bulb and test it against the fixture. The UV bulb, however, costs $25, which would cost each group member an additional $5. Before I decide to purchase another bulb for testing, I will confront them about the issue and ask of their opinions.

Additionally, tomorrow (Monday) I plan on contacting a light bulb company to ask if they might have an idea as to how to pursue this issue. When unsure, I believe it is wise to ask for professional help. After completing all of the above, I believe the issue will certainly be identified, and then fixed.

Friday, April 15, 2016

Daily Post 8

Well, we have indeed recieved a few of the parts. Three of them to be exact, including two of the reservoirs as well as the UV fixture and UV bulb.

However...

We attempted to test how well the fixture would work with the UV bulb and watched as a small puff of smoke arose from inside the UV bulb. To our horror, we have fried the UV bulb, and must figure out what exactly happen so we can make adjustments to the design.

I've begun to do research today regarding the possible error, and so far I think it may have had to deal with voltage, but I'm not entirely sure yet. I will update the status of my research tomorrow.

Thursday, April 14, 2016

Daily Post 7: Still waiting

I've gotten confirmation of a few packages being delivered for me yesterday, and I suspect that they are most likely parts for the project. I'm very excited to take a look at what we've recieved so far. If I had to guess, I'd say we probably have received the UV Fixture as well as the 3 gallon reservoir. Honestly there isn't too much he was assemble with just those parts, but hey, it's a start.

Receiving Parts

We have gotten many confirmation emails that orders for parts have shipped. In the following couple of days we should start having parts delivered and then assembly can begin.

Tuesday, April 12, 2016

Filter Functions

Filtration Type
Substances Removed
Course Filter
Large Particulate
Fine Filter
Small Particulate
Carbon Filter
Chlorine, Sediment, Volatile Organic Compounds, Taste, and Odor
Reverse Osmosis
Dissolved Ions, and Most Bacteria
UV Light
All Living Bacteria

Rough Overview Design